  kemet emc filters 1 flle2 pv dc emi filters for pv inverters overview this filter series is intended to be used in photo voltaic applications between the solar panels and the inverter system. th e filters are optimized in geometry and for power loss . they are also adapted to attenuate high frequency noise that may be degrading life time of the solar panels and will as well reduce the radiation of emi noise that may emerge from the panels. filters without y - capacitors to protective earth are a vailable on request. as the capacitance company , kemet is only using high quality capacitors in its filter series . technical specifications rated voltage 1200 vdc rated current 25 C 1600 a rated temperature 55c temperature range - 40c to +100c climate category 40/100/21 voltage test p - > p 3000 vdc p - > e 3600 vdc the flle2pv - series is designed according to iec/en 60939 and ul 1283. typical insertion loss 25 to 75 a 100 and 150 a 250 to 1600 a filter rated current @ 55c (a) power loss @ 25c/dc (w) weight (kg) flle2025apvr1 25 8 1 flle2050apvr1 50 12 2 flle2075apvr1 75 16 2 flle2100apvr1 100 20 3 flle2150apvr1 150 30 4 flle2250apvi1 250 10 5 flle2400apvi1 400 15 7 FLLE2600APVI1 600 25 7 flle2800apvi1 800 30 10 flle21k0apvi1 1000 45 10 flle21k6apvi1 1600 70 16 0.01 0.1 1 10 100 mhz 0 20 40 60 80 100 db sym asym 0.01 0.1 1 10 100 mhz 0 20 40 60 80 100 db sym asym 0.01 0.1 1 10 100 mhz 0 20 40 60 80 100 db sym asym pv array + _ pe inverter + _ pe
kemet emc filters 2 flle2 pv dc emi filters for pv inverters mechanical dimensions flle2 pv i 1 busbar connections flle2 pvr1 terminal blocks terminal blocks C wire dimensions 25a 16/10mm2 solid/flexible 50a 35/25 75a 35/25 100a 50/50 150a 95/95 250 to 1000a 1600 a filter dimensions in mm l w h l1 l2 w1 w2 u x y z i j k n m flle2025apvr1 140 80 65 170 45 60 25 m5 flle2050apvr1 170 95 80 200 60 75 39 m6 flle2075apvr1 170 95 80 200 60 75 39 m6 flle2100apvr1 190 125 95 220 80 100 45 m8 flle2150apvr1 220 140 115 250 100 120 50 m10 flle2250apvi1 300 130 110 130 110 155 180 70 5 25 58 15 9 m10 flle2400apvi1 300 140 110 130 110 165 190 70 6 25 58 15 10.5 m10 FLLE2600APVI1 300 140 110 130 110 165 190 70 8 40 58 15 10.5 m10 flle2800apvi1 300 150 140 130 110 175 200 70 8 40 65 20 14 m12 flle21k0apvi1 300 150 140 130 110 175 200 70 8 40 65 20 14 m12 flle21k6apvi1 300 150 150 130 110 175 200 70 10 60 100 17 43 26 14 m12 legal disclaimer notice all product specifications, statements, information and data (collectively, the information) are subject to change without notice. all information given herein is believed to be accurate and reliable, but is presented without guarantee, warranty, or responsibility of any kind, expressed or implied. statements of suitability for certain applications are based on our knowl edge of typical operating conditions for such applications, but are not intended to constitute C and we specifically disclaim C any warranty concerning suitability for a specific customer application or use. this information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their applications. any technical advice inferred from this information or otherwise p rovided by us with reference to the use of our products is given gratis, and we assume no obligation or liability for the advice given or results obtained. although we design and manufacture our products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still occur. accordingly, customer applicati ons which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies) in order to ensure that failure of an electrical component does not result in a risk of personal injury or property damage. although all product - related warnings, cautions and notes must be observed , the customer should not assume that all safety measures are indicated or that other measures may not be required l w h u y x z w1 w2 z l1 l2 ?12 (x6) l w h z z w1 w2 l1 r3 (x4) m k j i i ? n ? n


▲Up To Search▲   

 
Price & Availability of FLLE2600APVI1

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X